For PCB

This type of transformer is designed for installation into PCB. Primary and secondary voltage is configured based on customer specification. Transformers can be produced with additional windings with various parameters and primary or secondary windings with terminals with various voltages.

Technical specifications

Output

[VA]

Dimensions [mm]

Weight

[kg]

b

c

d

g2

g3

a [°]

b [°]

20

69,3

39,2

64

5,6

8

22,5

22,5

0,4

50

90

44,1

83,6

6,4

10

15

22,5

0,8

100

110,3

54,3

104

8,2

13

15

15

1,45

 

Output

[VA]

Dimesions (mm)

Weight

[kg]

a

b

c

d

e1

e2

f1

f2

g1

g2

g3

20

80

63,1

43,3

17,3

70

5x5

50

50

3,4

5,1

7

0,45

35

90,2

73,2

43,4

17,3

80

7x5

60

60

3,4

5,1

7

0,6

50

100

83,5

43,4

17,3

90

9x5

70

70

3,4

5,1

7

0,8

70

110

93,3

50,5

17,3

100

11x5

80

80

3,4

6,1

10

1,2

100

120

103

55,5

17,3

110

13x5

90

90

3,4

6,1

10

1,55

 

Tolerance of secondary voltage +/- 5% with nominal primary voltage 230 V